Default Limits: 0.0°C - 70.0°C
Total Rules: 16
Rules are checked in order, first match wins. Exact match on sensor_type, pattern match on sensor_descr.
| Sensor Type | Pattern (in descr) | Low Limit | High Limit |
|---|---|---|---|
entity-sensor |
** | °C | °C |
airos-af |
*Radio* | -40.0°C | 75.0°C |
ceraos |
*Amplifier* | 0.0°C | 80.0°C |
ceraos |
*IDU* | 0.0°C | 80.0°C |
eaton-mgeups |
*Ambient* | 0.0°C | 55.0°C |
eaton-sc200 |
*Battery* | -10.0°C | 50.0°C |
eaton-sc200 |
*Rect* | -10.0°C | 70.0°C |
rfc1628 |
*Battery* | -10.0°C | 50.0°C |
routeros |
*cpu* | 0.0°C | 90.0°C |
routeros |
*sfp* | 0.0°C | 80.0°C |
routeros |
*board* | 0.0°C | 80.0°C |
routeros |
*switch* | 0.0°C | 90.0°C |
routeros |
*temperature* | 0.0°C | 80.0°C |
swos |
*Processor* | 0.0°C | 90.0°C |
swos |
*SFP* | 0.0°C | 80.0°C |
tachyon |
** | °C | °C |
Total Rules: 22
Rules are checked in order, first match wins. Special handlers provide dynamic limits.
| Sensor Type | Pattern (in descr) | Handler | Description |
|---|---|---|---|
entity-sensor |
*PSU 1 Input* | ac | AC Power: 216-253V |
entity-sensor |
*PSU 2 Input* | ac | AC Power: 216-253V |
entity-sensor |
*PSU 1 Output* | static | {'nominal': 12.0, 'tolerance_percent': 5.0} |
entity-sensor |
*PSU 2 Output* | static | {'nominal': 12.0, 'tolerance_percent': 5.0} |
apc |
*Input* | ac | AC Power: 216-253V |
apc |
*Output* | ac | AC Power: 216-253V |
eaton-sc200 |
*Input* | ac | AC Power: 216-253V |
eaton-sc200 |
*AC* | ac | AC Power: 216-253V |
eaton-sc200 |
*Bus* | battery | Battery: Auto-detect (11.5-14.7V per 12V battery) |
eaton-sc200 |
*DC* | battery | Battery: Auto-detect (11.5-14.7V per 12V battery) |
edgeos-ep |
*Input Voltage PSU* | battery | Battery: Auto-detect (11.5-14.7V per 12V battery) |
edgeos-ep |
*Output Voltage* | poe | PoE: 24V (21-27V) or 48V (44-57V) |
rfc1628 |
*Battery* | battery | Battery: Auto-detect (11.5-14.7V per 12V battery) |
rfc1628 |
*Bypass* | ac | AC Power: 216-253V |
rfc1628 |
*Input* | ac | AC Power: 216-253V |
rfc1628 |
*Output* | ac | AC Power: 216-253V |
ceraos |
*voltage* | poe | PoE: 24V (21-27V) or 48V (44-57V) |
routeros |
*sfp* | sfp | SFP: 3.3V ±10% (2.97-3.63V) |
routeros |
*SFP* | sfp | SFP: 3.3V ±10% (2.97-3.63V) |
routeros |
*POE* | poe | PoE: 24V (21-27V) or 48V (44-57V) |
routeros |
*voltage* | battery | Battery: Auto-detect (11.5-14.7V per 12V battery) |
swos |
*SFP* | sfp | SFP: 3.3V ±10% (2.97-3.63V) |
Total Rules: 3
Optical power levels for SFP modules.
| Sensor Type | Pattern (in descr) | Handler | Description |
|---|---|---|---|
entity-sensor |
** | ||
routeros |
*Tx* | sfp_tx | SFP Transmit: -10 to +3 dBm |
routeros |
*Rx* | sfp_rx | SFP Receive: -20 to 0 dBm |
Total Rules: 3
Electrical current measurements in Amps.
| Sensor Type | Pattern (in descr) | Handler | Description |
|---|---|---|---|
routeros |
*POE* | poe | PoE Current: 0-0.8A (covers 802.3af and 802.3at) |
routeros |
*Tx Bias* | sfp_bias | SFP Tx Bias: 0-0.1A (100mA) |
swos |
*Bias* | sfp_bias | SFP Tx Bias: 0-0.1A (100mA) |
Total Rules: 1
Power consumption in Watts.
| Sensor Type | Pattern (in descr) | Handler | Description |
|---|---|---|---|
routeros |
*POE* | poe | PoE Power: 0-35W (covers 802.3af and 802.3at) |